Main page » Grease - Lubrication » Piston Pump for grease » Type KFA » Mini-Pump Units KFA-without Control
Mini-Pump Units KFA-without Control
Function principle | electrically operated piston pump |
Operating temperature | -25 to +75 °C |
Operating pressure | 300 bar; 4 350 psi |
Lubricant | grease up to NLGI 2 |
Outlets | 1 to 2 |
Metering quantity | 1,0; 1,5; 2,0 cm3/min 0.061; 0.092; 0.122 in3/min |
Reservoir | 1 l; 0.26 gal |
Connection main line | M 14 × 1 5 |
Operating voltage | 12 and 24 V DC; 115 V AC; (± 10%) |
Protection class | IP 6K9K |
Dimensions | 216 × 150 × 234,5 mm 8.1 × 5.9 × 9.2 |
KFA series pumps include a maximum of two outlet ports to connect two independent lubrication circuits A separate pump element is required for each outlet Three pump elements with different delivery rates are available so that the volume of grease can be adjusted to individual circuit needs This ensures that every lubrication point is supplied with an adequate amount of grease in each lubrication cycle Model KFAS has an integrated IG502-2-1 control and monitoring unit that operates in a time- or load- (pulse) dependent mode, with or without monitoring
Features and beneits
Integrated control system provides:
- Non-volatile memory with PIN-code protection
- Storage of residual interval, lubricating cycle and faults signals
- Saved data in event of a power failure
- Connection for external pushbutton and inductive cycle switch
- Interval and contact times can be set independently
- Fits in tight/small places
Applications
- Commercial vehicles
- Machine tools
- Printing industry
Unfortunately there are no reviews yet. Be the first who rates this product.